3.6 V Primary lithium-thionyl chloride (Li-SOCl
2) High power D-size spiral cell
Main applications
●
Radiocommunication and other military applications
●
● Beacons and emergency location transmitters
●
GPS
● Metering systems
● Sonobuoys
● Tracking systems
● GSM communication
NATO stock number 6135 14 440 1213
Physical characteristics
Diameter (max) 33.4 mm (1.32 in)
Height (max) 61.6 mm (2.42 in)
Typical weight 100 g (3.5 oz)
Li metal content approx. 3.8 g
Available termination suffix
CN, CNR radial tabs
CNA (AX) axial leads
FL flying leads ...etc
Cell size references UM1 – R20 – D
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.)
Nominal capacity 13.0 Ah
(at 15 mA + 20°C 2.0 V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off)
Open circuit voltage (at + 20°C) 3.67 V
Nominal voltage (at 2 mA + 20°C) 3.6 V
Pulse capability: Typically up to 4000 mA
(4000 mA/0.1 second pulses, drained every 2 mn at + 20°C from
undischarged cells with 10 μA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell's previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current 1800 mA
(to maintain cell heating within safe limits. Battery packs may imply lower
level of maximum current and may request specific thermal protection.
Consult Saft)
Storage (recommended) + 30°C (+ 86°F) max
(for more severe conditions, consult Saft)
Operating temperature range - 60°C/+ 85°C
(Operation above ambient T may lead to reduced capacity and (- 76°F/+ 185°F)
lower voltage readings at the beginning of pulses. Operation with
current continuously above 1 A may restrict upper T range. Consult Saft)
The Saft LSH cylindrical primary lithium cells are based on Lithium-Thionyl chloride (Li-SOCl2) chemistry and feature high surface area spiral electrodes for maximum current capability.
They are designed for applications requiring continuous currents in the 0.1-1.8 A range, with superimposed pulses as high as 4 A.
CONSTRUCTION FEATURES
- spiral electrodes
- stainless steel container
- hermetic and sturdy glass-to-metal sealing
- built-in safety vents
- individual cells with 5.5 A non-resettable fuse
- available as individual batteries (size C and D; with or without tabs) or multi-cell battery packs
MAIN APPLICATIONS
- utility metering
- automated meter reading
- alarms and security wireless devices
- mobile asset tracking
- GPS
- emergency location transmitters beacons (ELTs, EPIRBs)
- professional electronics
- military radiocommunication
- sonobuoys
- oil exploration
- automotive telematics
- telemetry
BENEFITS
- High operating voltage, stable during most of the application lifetime
- Good pulse capability
- Wide operating temperature range (-60°C to +70°C), +120°C for some cell versions
- Good resistance to passivation
- Non-flammable (and non-pressurized at ambient temperature), inorganic (but corrosive) electrolyte
- Less than 3% capacity loss per year, during storage at ambient temperature before use
- Performance independent from cell orientation
- Up to 25 years of mass production experience
- Compliant with the European directive RoHS
- Good safety records
Technical characteristics |
- 3.67 V open circuit voltage
- Operating voltage (depending on conditions) typically above 3 V
- Underwriters Laboratories (UL) Component Recognition (File number MH 12609)
- Compliance with IEC 60086-4
Cell type constuction | C | C | D | D |
Open Circuit Voltage | 3.67 V | 3.67 V | 3.67 V | 3.67 V |
Nominal Voltage | 3.6 V | 3.6 V | 3.6 V | 3.6 V |
Nominal capacity (drain) | 5.8 Ah (15 mA) | 3.6 Ah (15 mA) | 13.0 Ah (15 mA) | 14.0 Ah (300 mA) |
Max. recom. Cont. Current | 1.3 A | 1.3 A | 1.8 A | Consult Saft |
Operating temp. range | -60/+85°C * | -60/+85°C * | -60/+85°C * | -40/+150°C |
Outside diameter max | 26.0 mm | 26.0 mm | 33.4 mm | 32.05 mm |
Length max | 50.4 mm | 50.4 mm | 61.6 mm | 61.7 mm |
Weight | 51 g | 51 g | 100 g | 104.5 g |
Transport | Restricted (Class 9) | Non-restricted | Restricted (Class 9) | Restricted (Class 9) |
Niciun comentariu: