sâmbătă, 3 noiembrie 2012

Saft LSH20 Baterie Litiu (Li-SOCl2)



        





Primary lithium battery Saft LSH 20

3.6 V Primary lithium-thionyl chloride (Li-SOCl
2High power D-size spiral cell 

Main applications

● 
Radiocommunication and other military applications

● 

Alarms and security systems

●  Beacons and emergency location transmitters
● 
GPS
●  Metering systems
●  Sonobuoys
●  Tracking systems
●  GSM communication

NATO stock number  6135 14 440 1213


Physical characteristics

Diameter (max) 33.4 mm (1.32 in)

Height (max) 61.6 mm (2.42 in)

Typical weight 100 g (3.5 oz)
Li metal content approx. 3.8 g
Available termination suffix
CN, CNR radial tabs
CNA (AX) axial leads
FL flying leads ...etc



Cell size references UM1 – R20 – D

Electrical characteristics

(typical values relative to cells stored for one year or less at + 30°C max.)

Nominal capacity 13.0 Ah
(at 15 mA + 20°C 2.0 V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off)
Open circuit voltage (at + 20°C) 3.67 V
Nominal voltage (at 2 mA + 20°C) 3.6 V
Pulse capability: Typically up to 4000 mA
(4000 mA/0.1 second pulses, drained every 2 mn at + 20°C from
undischarged cells with 10 μA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell's previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current 1800 mA
(to maintain cell heating within safe limits. Battery packs may imply lower
level of maximum current and may request specific thermal protection.
Consult Saft)
Storage (recommended) + 30°C (+ 86°F) max
(for more severe conditions, consult Saft)
Operating temperature range - 60°C/+ 85°C
(Operation above ambient T may lead to reduced capacity and (- 76°F/+ 185°F)
lower voltage readings at the beginning of pulses. Operation with
current continuously above 1 A may restrict upper T range. Consult Saft)
The Saft LSH cylindrical primary lithium cells are based on Lithium-Thionyl chloride (Li-SOCl2) chemistry and feature high surface area spiral electrodes for maximum current capability.
They are designed for applications requiring continuous currents in the 0.1-1.8 A range, with superimposed pulses as high as 4 A.

 Download RealPlayer for FREE



CONSTRUCTION FEATURES

  • spiral electrodes
  • stainless steel container
  • hermetic and sturdy glass-to-metal sealing
  • built-in safety vents
  • individual cells with 5.5 A non-resettable fuse
  • available as individual batteries (size C and D; with or without tabs) or multi-cell battery packs

MAIN APPLICATIONS

  • utility metering
  • automated meter reading
  • alarms and security wireless devices
  • mobile asset tracking
  • GPS
  • emergency location transmitters beacons (ELTs, EPIRBs)
  • professional electronics
  • military radiocommunication
  • sonobuoys
  • oil exploration
  • automotive telematics
  • telemetry

BENEFITS

  •  High operating voltage, stable during most of the application lifetime
  • Good pulse capability
  • Wide operating temperature range  (-60°C to +70°C),  +120°C for some cell versions
  • Good resistance to passivation 
  • Non-flammable (and non-pressurized at ambient temperature),  inorganic (but corrosive) electrolyte
  • Less than 3% capacity loss per year, during storage at ambient temperature before use
  • Performance independent from cell orientation
  • Up to 25 years of mass production experience
  • Compliant with the European directive RoHS
  • Good safety records
Technical characteristics


  • 3.67 V open circuit voltage
  • Operating voltage (depending on conditions) typically above 3 V
  • Underwriters Laboratories (UL) Component  Recognition (File number MH 12609)
  • Compliance with IEC 60086-4 
Cell type constuctionCCDD
Open Circuit Voltage3.67 V3.67 V3.67 V3.67 V
Nominal Voltage3.6 V3.6 V3.6 V3.6 V
Nominal capacity (drain)5.8 Ah (15 mA)3.6 Ah (15 mA)13.0 Ah (15 mA)14.0 Ah (300 mA)
Max. recom. Cont. Current1.3 A1.3 A1.8 AConsult Saft
Operating temp. range-60/+85°C *-60/+85°C *-60/+85°C *-40/+150°C
Outside diameter max26.0 mm26.0 mm33.4 mm32.05 mm
Length max50.4 mm50.4 mm61.6 mm61.7 mm
Weight51 g51 g100 g104.5 g
TransportRestricted
(Class 9)
Non-restrictedRestricted
(Class 9)
Restricted
(Class 9)