Electrical characteristics
(typical values relative to cells stored for one year or less at +30°C max.)
Nominal capacity 1.20 Ah
(at 1 mA +20°C 2.0 V cut -off. The capacity restored by the cell varies
according to current drain, temperature and cut -off
Open circuit voltage (at +20°C) 3.67 V
Open circuit voltage (at +20°C) 3.67 V
Nominal voltage (at 0.1 mA +20°C) 3.6 V
Nominal energy 4.32 Wh
(100 mA/0.1 second pulses, drained every 2 mn at +20°C from
undischarged cells with 10 µA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell’s previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current 35 mA
(Higher currents are possible, consult Saft)
Storage (recommended) +30°C (+86°F) max
(for more severe conditions, consult Saft)
Operating temperature range -60°C/+85°C
(Operation above ambient T may lead to reduced capacity and (-76°F/+185°F)
lower voltage readings at the beginning of pulses. Consult Saft)
Physical characteristics
Diameter (max) 14.55 mm (0.57 in)
Height (max) 25.15 mm (0.99 in)
Typical weight 8.9 g (0.3 oz)
Li metal content approx. 0.3 g